🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

Actisense EMU-1-BAS Engine Monitoring Unit - NMEA 2000

Actisense EMU-1-BAS Engine Monitoring Unit - NMEA 2000

EMU-1Ā NMEA 2000Ā® Engine Monitoring Unit

EMU-1-BAS

EMU-1 - Convert your Analog engine data to NMEA 2000.Ā 

(Please note that an Actisense NGX-1-USB or NGX-1-ISO,Ā  is required to configure the EMU-1.Ā  This is an optional item and is not included with the EMU-1)

Actisense Gateways

The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine senders into NMEA 2000. The EMU-1 enables NMEA 2000 display devices to monitor the engine on a vessel.
Ā 
The EMU-1 has a PC based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models. Capable of measuring a wide range of engine parameters, the EMU-1 reports how the engine is operating and shares the information across the network.
Ā 
Designed to simplify the conversion of analogue engine parameters (e.g. Temperature, pressure and RPM) into NMEA 2000 engine PGNs, the EMU-1 simplifies processes and reduces the number of input/output wires required at each engine. Additionally, the EMU-1 also supports the conversion of analogue transmission parameters and battery status to the associated NMEA 2000 PGN's.
Ā 
The two-part screw terminal connection system allows for an easy pluggable connection to an engine wiring harness.
Ā 
Multiple engines are supported by the setting of the engine instance using the EMU-1 configuration tool. Currently one EMU-1 per engine is supported. Support for multiple engines on a single EMU-1 is currently planned as a future firmware update. Ā 
Ā 
The customized case ensures that the electronics are sealed while allowing quick access to the electrical connections.
Ā 
An optional DIN rail mounting kit is also available. The kit is suitable for use with a top hat rail, type EN 50 022 or a G section rail, type EN 50 035. Please order the DIN rail kit using part number: DIN-KIT-1.
Ā 
It is recommended that an Actisense NGX-1 NMEA 2000 Gateway is available for every EMU-1 installation as the EMU-1 can not be configured without one. The NGX-1 can also be used to update the Firmware, connect the Configuration Tool and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the Actisense Engine Monitoring Solution page for product details.

Now Includes Support for Tilt & Trim Tabs!

FEATURES

  • Enables analogue signals to be converted to NMEA 2000 messages
  • Convert signals from up to two engines (that share a common ground) with a single EMU-1
  • 6 gauge / parameter inputs
  • 4 alarm inputs
  • 2 additional auxiliary inputs
  • 2 Tacho inputs
  • Customised IP65 case
  • Diagnostic LED’s
  • Wide power compatibility of 9 to 35 Vdc

BENEFITS

  • No need to change an existing engine
  • Easy installation
  • Easy to configure to suit the connected engine
  • Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000Ā®
  • Optional DIN rail mounting kit available
  • Total engine hours are logged by the monitoring of engine Tach (RPM) input

Ordering Information

(Part number/s)

  • EMU-1

CONFIGURATION INFORMATION

Every EMU-1Ā MUSTĀ be configured to work with each installation.Ā 

NETWORK DIAGRAM

TECHNICAL SPECIFICAIONS

Power Supply
Supply Voltage 9 to 35V DC
Supply Current Typically < 25mA @ 12V DC
Supply Protection Continuous reverse polarity protection and load dump protection (meets SAE J1113)
Supply Connector Pluggable 2-way screw terminal, 3.5mm pitch
Supply Voltage (NMEA 2000 Port) 9 to 29V DC
Supply Current (NMEA 2000 Port) < 20mA @ 12V DC from NMEA 2000 bus
Load Equivalent Number (LEN) 1
Supply Protection (NMEA 2000 Port) Continuous reverse polarity protection and overvoltage protection to 40V
NMEA 2000 Port – In/Out
Compatibility Fully NMEA 2000 certified
Galvanic Isolation 2500V input to ground, 1500V output to ground using ISO-Drive
Speed / Baud Rate 250kbps
NMEA 2000 Connector M12 male (A coded) connector
Gauge Inputs
Voltage Range 0 to 35V DC
Input Impedance > 50kΩ
Sender Feed 0, 4 or 18mA
Accuracy <= 2%
Input Connector Pluggable 6-way screw terminal, 3.5mm pitch
Input Protection Overvoltage protection to ±40V
Alarm Inputs
Voltage Range 0 to 37V DC
Input Impedance > 50kΩ
Threshold Voltage Configurable, default is 5V
Alarm Polarity Configurable, default is alarm on low input
Accuracy <= 2%
Input Connector Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection Overvoltage protection to ±40V
Tacho Inputs
Voltage Range ±3 to ±60V
Input Impedance > 100kΩ to ground
Input Pulse Range 4 to 50,000Hz
Accuracy <= 1%
Sender Compatibility Ignition coil, alternator (ā€œWā€, ā€œRā€ or ā€œACā€) terminal, hall effect, VR or inductive sender
Threshold Automatically adjusts to signal level
Input Connector Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection Can withstand an ignition pulse to ±500V
Engine Log
Engine Hours 2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memory
Mechanical
Housing Material Polycarbonate
Protective Lid Material Polycarbonate
Sealing Materials Expanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
Dimensions 127mm (L) x 112mm (W) x 48mm (H)
Weight 250g
Mounting 4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request
Approvals and Certifications
Fully NMEA 2000 Certified
EMC EN 60945 (sections 9 & 10)
Environmental Protection IP66 (PCB housing)
Operating Temperature -20°C to +55°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 – 93% RH
Warranty Manufacturer's 3 years

Ā 

Video

$167.99

Original: $559.95

-70%
Actisense EMU-1-BAS Engine Monitoring Unit - NMEA 2000—

$559.95

$167.99
Product image 1
Product image 2
Product image 3
Product image 4

Description

EMU-1Ā NMEA 2000Ā® Engine Monitoring Unit

EMU-1-BAS

EMU-1 - Convert your Analog engine data to NMEA 2000.Ā 

(Please note that an Actisense NGX-1-USB or NGX-1-ISO,Ā  is required to configure the EMU-1.Ā  This is an optional item and is not included with the EMU-1)

Actisense Gateways

The Actisense EMU-1 is a specialized analogue to NMEA 2000 Gateway which converts data from analogue engine senders into NMEA 2000. The EMU-1 enables NMEA 2000 display devices to monitor the engine on a vessel.
Ā 
The EMU-1 has a PC based configuration tool that allows the settings inside the EMU-1 to be changed to best suit the engine it is working with, making it a flexible solution for many engine makes and models. Capable of measuring a wide range of engine parameters, the EMU-1 reports how the engine is operating and shares the information across the network.
Ā 
Designed to simplify the conversion of analogue engine parameters (e.g. Temperature, pressure and RPM) into NMEA 2000 engine PGNs, the EMU-1 simplifies processes and reduces the number of input/output wires required at each engine. Additionally, the EMU-1 also supports the conversion of analogue transmission parameters and battery status to the associated NMEA 2000 PGN's.
Ā 
The two-part screw terminal connection system allows for an easy pluggable connection to an engine wiring harness.
Ā 
Multiple engines are supported by the setting of the engine instance using the EMU-1 configuration tool. Currently one EMU-1 per engine is supported. Support for multiple engines on a single EMU-1 is currently planned as a future firmware update. Ā 
Ā 
The customized case ensures that the electronics are sealed while allowing quick access to the electrical connections.
Ā 
An optional DIN rail mounting kit is also available. The kit is suitable for use with a top hat rail, type EN 50 022 or a G section rail, type EN 50 035. Please order the DIN rail kit using part number: DIN-KIT-1.
Ā 
It is recommended that an Actisense NGX-1 NMEA 2000 Gateway is available for every EMU-1 installation as the EMU-1 can not be configured without one. The NGX-1 can also be used to update the Firmware, connect the Configuration Tool and display data on a PC for diagnostic and information purposes, using NMEA Reader. Please visit the Actisense Engine Monitoring Solution page for product details.

Now Includes Support for Tilt & Trim Tabs!

FEATURES

  • Enables analogue signals to be converted to NMEA 2000 messages
  • Convert signals from up to two engines (that share a common ground) with a single EMU-1
  • 6 gauge / parameter inputs
  • 4 alarm inputs
  • 2 additional auxiliary inputs
  • 2 Tacho inputs
  • Customised IP65 case
  • Diagnostic LED’s
  • Wide power compatibility of 9 to 35 Vdc

BENEFITS

  • No need to change an existing engine
  • Easy installation
  • Easy to configure to suit the connected engine
  • Connect signals from fluid level gauges (that share a common ground with the engine) to NMEA 2000Ā®
  • Optional DIN rail mounting kit available
  • Total engine hours are logged by the monitoring of engine Tach (RPM) input

Ordering Information

(Part number/s)

  • EMU-1

CONFIGURATION INFORMATION

Every EMU-1Ā MUSTĀ be configured to work with each installation.Ā 

NETWORK DIAGRAM

TECHNICAL SPECIFICAIONS

Power Supply
Supply Voltage 9 to 35V DC
Supply Current Typically < 25mA @ 12V DC
Supply Protection Continuous reverse polarity protection and load dump protection (meets SAE J1113)
Supply Connector Pluggable 2-way screw terminal, 3.5mm pitch
Supply Voltage (NMEA 2000 Port) 9 to 29V DC
Supply Current (NMEA 2000 Port) < 20mA @ 12V DC from NMEA 2000 bus
Load Equivalent Number (LEN) 1
Supply Protection (NMEA 2000 Port) Continuous reverse polarity protection and overvoltage protection to 40V
NMEA 2000 Port – In/Out
Compatibility Fully NMEA 2000 certified
Galvanic Isolation 2500V input to ground, 1500V output to ground using ISO-Drive
Speed / Baud Rate 250kbps
NMEA 2000 Connector M12 male (A coded) connector
Gauge Inputs
Voltage Range 0 to 35V DC
Input Impedance > 50kΩ
Sender Feed 0, 4 or 18mA
Accuracy <= 2%
Input Connector Pluggable 6-way screw terminal, 3.5mm pitch
Input Protection Overvoltage protection to ±40V
Alarm Inputs
Voltage Range 0 to 37V DC
Input Impedance > 50kΩ
Threshold Voltage Configurable, default is 5V
Alarm Polarity Configurable, default is alarm on low input
Accuracy <= 2%
Input Connector Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection Overvoltage protection to ±40V
Tacho Inputs
Voltage Range ±3 to ±60V
Input Impedance > 100kΩ to ground
Input Pulse Range 4 to 50,000Hz
Accuracy <= 1%
Sender Compatibility Ignition coil, alternator (ā€œWā€, ā€œRā€ or ā€œACā€) terminal, hall effect, VR or inductive sender
Threshold Automatically adjusts to signal level
Input Connector Pluggable 4-way screw terminal, 3.5mm pitch
Input Protection Can withstand an ignition pulse to ±500V
Engine Log
Engine Hours 2 separate engine hour logs internally connected to the tacho Inputs. Hours are logged when RPM is present, stored in non-volatile memory
Mechanical
Housing Material Polycarbonate
Protective Lid Material Polycarbonate
Sealing Materials Expanded silicone foam gasket, closed cell polyurethane splash guard and ePTFE waterproof vent
Dimensions 127mm (L) x 112mm (W) x 48mm (H)
Weight 250g
Mounting 4 x 3.5mm lugs to allow panel mount with self tapping s/s screws (included), optional DIN Rail mount available on request
Approvals and Certifications
Fully NMEA 2000 Certified
EMC EN 60945 (sections 9 & 10)
Environmental Protection IP66 (PCB housing)
Operating Temperature -20°C to +55°C
Storage Temperature -30°C to +70°C
Recommended Humidity 0 – 93% RH
Warranty Manufacturer's 3 years

Ā 

Video